Some do this and setup a limited number of circuits to be powered off the F-150 generator.Īlternatively you can install a neutral switching box in your house. Most setups only switch the two hot wires from line to generator, but a neutral switching box also switches the neutral from line to generator.

This breaks the neutral-ground bond inside the house.

That is not necessarily the best way to do it, so I'm awaiting Ford to make a serious technical response.Īlternatively you can install a neutral switching box in your house. Simplistically, it is as simple as disconnecting the ground cable from the neutral cable somewhere in the truck. If you can find a knowledgeable (licensed) electrician, he could make that conversion for you. The dealer has gone back to ask for a better answer. I have approached Ford via my sales & servicing dealer. OSHA requires the neutral-ground bond, not the NEC. The Powerboost generators are set up for contractor on site support.
Generlink transfer switch generator#
Interestingly that is how the 2.0 kW generator in a non-Powerboost F-150 is set up. The simplest fix is to convert the truck generator to a floating neutral (ie no neutral-ground bond). As I understand it those circulating currents can get large enough to be dangerous. The NEC requires only one neutral-ground bond because odd circulating currents can be setup if there is more than one neutral-ground bond. If you break the ground wire between the truck and the house it'll work fine. Interestingly, his generator does not detect this as a fault and continues functioning.įirst: the Powerboost electronics senses the neutral-ground bond inside your house as a "gound." Thus is shuts down the generator. I suspect that youtuber answers my question at 22:50 where he temporarily "bonds" his generator and measures current on the ground wire between generator and home panel. Is it checking for a "ground - neutral continuity" in whatever is plugged in to the receptacle? This video made a surprising amount of sense to me but I still don't understand why having neutral and ground bounded in two places (the home's panel and the truck) is a problem when having them bonded in only one place (the home's panel) is not, nor do I understand how the truck detects that condition. I just had an electrician at my house to discuss setting up the powerboost as a whole house backup generator, and despite my mentioning other people have had problems with ground faults due to the "bonded neutral" generator on the truck he was not dissuaded at all and was confident an interlock on the main panel would work. Call for details.Can someone clearly write out why the powerboost generator won't work with a typical interlock switch in the main panel, in a way that a reasonably competent electrician (that hasn't spent hours reading this thread) would understand? *Price includes tax and installation costs. Surge protection and additional cord lengths are available for an additional cost.

Generlink transfer switch full#
A larger compatible generator can used, but full output of the generator will not be utilized.